UltraSeal®
Drainage Tube Fixing Device.
Product Description
- Suture-free, no stretching pain or exposure to sharps, improves patients' comfort, and can be removed easily
- Effectively absorbs leaked fluid and exudates by inserting into the locking system
- The loop-like adjustable locking system not only reduces the operating time but also brings convenience to the daily care of medical staff because of its adjustable holding strips and double fixation design
5 Disadvantages Of The Traditional Catheter Suture-Securing Method

Excellently adaptable with a wide scope for all different sizes of drainage tubes and the catheters in the following surgical departments.
- Thoracic surgery
- Hepatobiliary and pancreatic surgery
- Postoperative drainage
- Orthopedic surgery drainage
- Ultrasound guided drainage after surgery
- Onco surgery drainage
Intended Use:
- UltraSeal® is intended to fix the drainage tube and change the traditional suturing method.
- Enhance the fixing force and avoid secondary trauma to the skin.
Contraindications:
- Do not use UltraSeal® to secure vascular catheter.
- Do not use UltraSeal® on infected\excessive exudation wounds or skin defected around the catheter
- Use with caution if patient is allergic to PSA tape.
Warnings:
- Single use only.
- Must clean and dry the application area before use.
- Change the UltraSeal® device regularly. The maximum time should not exceed 7 days.
- Contact the medical staff immediately if large amount of exudate occurs
- Check the incision, if there is any infection, tissue defect or excessive exudation, please treat it before using UltraSeal®
- Clean and dry the skin surrounding the intubating incision before applying UltraSeal®, to avoid the adhesive being weakened
Application of UltraSeal®

Pass the drainage catheter through the rotating ring. Tear off the #1 releasing paper marked as to expose the adhesive of the pad, then paste the device closely on the skin.

Rotate the loop (blue ring) clockwise, the hidden hoops will tighten tube as rotating. Do not use excessive force to rotate or tighten the tube too much.

Pass the drainage catheter through the rotating ring. Tear off the #1 releasing paper marked as to expose the adhesive of the pad, then paste the device closely on the skin.

Pass the drainage catheter through the rotating ring. Tear off the #1 releasing paper marked as to expose the adhesive of the pad, then paste the device closely on the skin.

Place the C-shape gauze around the drainage catheter to absorb exudate. Make sure the gauze touches the skin.

Rotate the loop (blue ring) clockwise, the hidden hoops will tighten tube as rotating. Do not use excessive force to rotate or tighten the tube too much.

Fasten two cable ties to stabilize the direction of the tube. Use appropriate force according to different materials or specification of catheters.

Place the C-shape gauze around the drainage catheter to absorb exudate. Make sure the gauze touches the skin.

Fasten two cable ties to stabilize the direction of the tube. Use appropriate force according to different materials or specification of catheters.

Adjust/Release the hoop band: Holding the unlock button on both sides of the rotating ring, and rotate anticlockwise the ring to loosen the hoop band.